Temperature setting range : 30 – 50°C
Temperature stability : ±2°C
Max. working pressure (static) : 10 bar
Max. working pressure (dynamic ): 5 bar
Max. inlet temperature : 85°C
Max. inlet pressure ratio (H/C or C/H) : 6:1
Minimum temperature difference between the inlet hot water and the outlet mixed water to ensure anti-scald performance : 10°C
Minimum flow rate for stable operation : 4 l/min